This is the latest recevied telemetry packets stored in our database for station/object OK2PYA-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1765965014 | 225 Count | 211 Count | 211 Count | 4.29 VDC | 0 VDC |
| 1765962124 | 161 Count | 150 Count | 150 Count | 4.29 VDC | 0 VDC |
| 1765961161 | 141 Count | 131 Count | 131 Count | 4.29 VDC | 0 VDC |
| 1765960198 | 119 Count | 110 Count | 110 Count | 4.29 VDC | 0 VDC |
| 1765958271 | 71 Count | 64 Count | 64 Count | 4.28 VDC | 0 VDC |
| 1765894105 | 66 Count | 64 Count | 64 Count | 4.29 VDC | 0 VDC |
| 1765893142 | 45 Count | 44 Count | 44 Count | 4.29 VDC | 0 VDC |
| 1765892178 | 25 Count | 25 Count | 25 Count | 4.29 VDC | 0 VDC |
| 1765891215 | 1004 Count | 946 Count | 946 Count | 4.29 VDC | 0 VDC |
| 1765888325 | 945 Count | 890 Count | 890 Count | 4.29 VDC | 0 VDC |
| 1765887362 | 916 Count | 862 Count | 862 Count | 4.29 VDC | 0 VDC |
| 1765886399 | 894 Count | 841 Count | 841 Count | 4.29 VDC | 0 VDC |
| 1765885431 | 874 Count | 822 Count | 822 Count | 4.29 VDC | 0 VDC |
| 1765884468 | 848 Count | 797 Count | 797 Count | 4.29 VDC | 0 VDC |
| 1765883505 | 826 Count | 776 Count | 776 Count | 4.29 VDC | 0 VDC |
| 1765882542 | 807 Count | 758 Count | 758 Count | 4.29 VDC | 0 VDC |
| 1765881578 | 788 Count | 740 Count | 740 Count | 4.29 VDC | 0 VDC |
| 1765879652 | 744 Count | 698 Count | 698 Count | 4.29 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)