This is the latest recevied telemetry packets stored in our database for station/object SQ1JKB-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1768189120 | 352 Count | 5 Count | 0 Count | 4.12 VDC | 0.14 VDC |
| 1768187317 | 351 Count | 5 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1768185514 | 350 Count | 5 Count | 0 Count | 4.12 VDC | 0.14 VDC |
| 1768183711 | 349 Count | 5 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1768181908 | 348 Count | 5 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1768180105 | 347 Count | 5 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1768178303 | 346 Count | 5 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1768176500 | 345 Count | 5 Count | 0 Count | 4.09 VDC | 0.14 VDC |
| 1768174697 | 344 Count | 5 Count | 0 Count | 4.1 VDC | 0.14 VDC |
| 1768172894 | 343 Count | 5 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1768171091 | 342 Count | 5 Count | 0 Count | 4.07 VDC | 0.14 VDC |
| 1768169288 | 341 Count | 5 Count | 0 Count | 4.06 VDC | 0.14 VDC |
| 1768167521 | 340 Count | 5 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1768165718 | 339 Count | 5 Count | 0 Count | 4.1 VDC | 0.14 VDC |
| 1768163915 | 338 Count | 5 Count | 0 Count | 4.1 VDC | 0.14 VDC |
| 1768162112 | 337 Count | 5 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1768160309 | 336 Count | 5 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1768158506 | 335 Count | 5 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1768156703 | 334 Count | 5 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1768154900 | 333 Count | 5 Count | 0 Count | 4.07 VDC | 0.14 VDC |
| 1768153097 | 332 Count | 5 Count | 0 Count | 4.12 VDC | 0.14 VDC |
| 1768151294 | 331 Count | 5 Count | 0 Count | 4.12 VDC | 0.14 VDC |
| 1768149491 | 330 Count | 5 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1768147688 | 329 Count | 5 Count | 0 Count | 4.13 VDC | 0.14 VDC |
| 1768145919 | 328 Count | 5 Count | 0 Count | 4.11 VDC | 0.14 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)