This is the latest recevied telemetry packets stored in our database for station/object SP3HUO-2. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1774442940 | 663 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774441138 | 657 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774439337 | 649 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774437536 | 643 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774435735 | 638 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774433933 | 633 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774432132 | 628 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774430331 | 623 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774428530 | 618 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774426728 | 613 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774424926 | 607 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774423125 | 602 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774421324 | 584 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774419550 | 576 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774417749 | 571 Count | 123 Count | 104 Count | 0 VDC | 0 VDC |
| 1774415948 | 548 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774414147 | 543 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774412346 | 538 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774410545 | 533 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774408743 | 528 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774406942 | 522 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774405141 | 517 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774403340 | 513 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774401539 | 508 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
| 1774399738 | 503 Count | 109 Count | 90 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)