This is the latest recevied telemetry packets stored in our database for station/object VK2GJ-12. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vbat* | Vsol* | Psys* | Temp* | AirP* |
---|---|---|---|---|---|
1745875588 | 4 V | 0 V | 210 mW | 25.5 degC | 100237.5 Pa |
1745873815 | 4 V | 0 V | 208 mW | 25.5 degC | 100212.5 Pa |
1745871990 | 4 V | 0 V | 214 mW | 25.9 degC | 100175 Pa |
1745870187 | 4 V | 0 V | 226 mW | 27.4 degC | 100162.5 Pa |
1745868413 | 4 V | 0 V | 216 mW | 26 degC | 100125 Pa |
1745866588 | 3.99 V | 0 V | 208 mW | 26.6 degC | 100087.5 Pa |
1745864790 | 4 V | 0 V | 224 mW | 27.2 degC | 100050 Pa |
1745863015 | 4 V | 0 V | 228 mW | 26.9 degC | 100062.5 Pa |
1745861192 | 4 V | 0 V | 214 mW | 26.1 degC | 100050 Pa |
1745859394 | 4 V | 0 V | 204 mW | 26.2 degC | 100062.5 Pa |
1745857617 | 4.01 V | 0 V | 218 mW | 27.3 degC | 100075 Pa |
1745855796 | 3.99 V | 0 V | 210 mW | 27.6 degC | 100100 Pa |
1745854880 | 4 V | 0 V | 366 mW | 30.3 degC | 100100 Pa |
1745852596 | 4 V | 0 V | 356 mW | 29.5 degC | 100150 Pa |
1745850221 | 4 V | 0 V | 364 mW | 30.6 degC | 100150 Pa |
1745847999 | 4 V | 0 V | 306 mW | 29.8 degC | 100137.5 Pa |
1745844452 | 4 V | 0 V | 304 mW | 29.6 degC | 100162.5 Pa |
1745839741 | 4 V | 0 V | 296 mW | 29.4 degC | 100162.5 Pa |
1745837490 | 4 V | 0 V | 294 mW | 29.1 degC | 100175 Pa |
1745835288 | 4 V | 0 V | 294 mW | 29 degC | 100162.5 Pa |
1745833038 | 4 V | 0 V | 296 mW | 29.4 degC | 100137.5 Pa |
1745830837 | 4 V | 0 V | 298 mW | 28.9 degC | 100112.5 Pa |
1745828584 | 4 V | 0 V | 304 mW | 28.9 degC | 100075 Pa |
1745826382 | 3.99 V | 0 V | 306 mW | 28.9 degC | 100012.5 Pa |
1745824132 | 4 V | 0 V | 304 mW | 29 degC | 99975 Pa |
*Used Equation Coefficients:
Vbat: 0, 0.001, 0
Vsol: 0, 0.001, 0
Psys: 0, 2, 0
Temp: 0, 0.1, -100
AirP: 0, 12.5, 500
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)