This is the latest recevied telemetry packets stored in our database for station/object SQ1JKB-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1770107531 | 419 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770105729 | 418 Count | 76 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1770103926 | 417 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770102123 | 416 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770100320 | 415 Count | 76 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1770098516 | 414 Count | 76 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1770096714 | 413 Count | 76 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1770094911 | 412 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770093108 | 411 Count | 76 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1770091305 | 410 Count | 76 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1770089502 | 409 Count | 76 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1770087734 | 408 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770085931 | 407 Count | 76 Count | 0 Count | 4.15 VDC | 0.14 VDC |
| 1770084129 | 406 Count | 76 Count | 0 Count | 4.09 VDC | 0.14 VDC |
| 1770082326 | 405 Count | 76 Count | 0 Count | 4.09 VDC | 0.14 VDC |
| 1770080523 | 404 Count | 76 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1770078720 | 403 Count | 76 Count | 0 Count | 4.12 VDC | 0.14 VDC |
| 1770076916 | 402 Count | 76 Count | 0 Count | 4.16 VDC | 0.14 VDC |
| 1770075113 | 401 Count | 76 Count | 0 Count | 4.08 VDC | 0.14 VDC |
| 1770073311 | 400 Count | 76 Count | 0 Count | 4.1 VDC | 0.14 VDC |
| 1770071508 | 399 Count | 76 Count | 0 Count | 4.11 VDC | 0.14 VDC |
| 1770069705 | 398 Count | 76 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1770067902 | 397 Count | 76 Count | 0 Count | 4.14 VDC | 0.14 VDC |
| 1770066132 | 396 Count | 76 Count | 0 Count | 4.1 VDC | 0.14 VDC |
| 1770064329 | 395 Count | 76 Count | 0 Count | 4.15 VDC | 0.14 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)