This is the latest recevied telemetry packets stored in our database for station/object OK1FWG-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1763881565 | 317 Count | 731 Count | 303 Count | 0 VDC | 0 VDC |
| 1763879762 | 314 Count | 688 Count | 302 Count | 0 VDC | 0 VDC |
| 1763877958 | 307 Count | 621 Count | 296 Count | 0 VDC | 0 VDC |
| 1763876155 | 283 Count | 565 Count | 273 Count | 0 VDC | 0 VDC |
| 1763874352 | 253 Count | 499 Count | 244 Count | 0 VDC | 0 VDC |
| 1763872549 | 218 Count | 436 Count | 211 Count | 0 VDC | 0 VDC |
| 1763870745 | 185 Count | 367 Count | 179 Count | 0 VDC | 0 VDC |
| 1763868942 | 156 Count | 312 Count | 151 Count | 0 VDC | 0 VDC |
| 1763867138 | 127 Count | 254 Count | 123 Count | 0 VDC | 0 VDC |
| 1763865330 | 95 Count | 191 Count | 93 Count | 0 VDC | 0 VDC |
| 1763863527 | 66 Count | 130 Count | 65 Count | 0 VDC | 0 VDC |
| 1763861724 | 27 Count | 59 Count | 27 Count | 0 VDC | 0 VDC |
| 1763859921 | 332 Count | 1059 Count | 309 Count | 0 VDC | 0 VDC |
| 1763858118 | 328 Count | 1000 Count | 307 Count | 0 VDC | 0 VDC |
| 1763856314 | 327 Count | 948 Count | 307 Count | 0 VDC | 0 VDC |
| 1763854510 | 324 Count | 902 Count | 305 Count | 0 VDC | 0 VDC |
| 1763852707 | 306 Count | 838 Count | 288 Count | 0 VDC | 0 VDC |
| 1763850900 | 270 Count | 767 Count | 254 Count | 0 VDC | 0 VDC |
| 1763849095 | 241 Count | 704 Count | 226 Count | 0 VDC | 0 VDC |
| 1763847292 | 218 Count | 646 Count | 204 Count | 0 VDC | 0 VDC |
| 1763845489 | 188 Count | 581 Count | 175 Count | 0 VDC | 0 VDC |
| 1763843686 | 162 Count | 520 Count | 151 Count | 0 VDC | 0 VDC |
| 1763841883 | 146 Count | 468 Count | 136 Count | 0 VDC | 0 VDC |
| 1763840080 | 124 Count | 413 Count | 115 Count | 0 VDC | 0 VDC |
| 1763838277 | 97 Count | 350 Count | 89 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)