This is the latest recevied telemetry packets stored in our database for station/object 2E1GRY-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Sate* | Temp* | Volt* | Alt* | A5* |
|---|---|---|---|---|---|
| 1762148516 | 10 | 21.8 C | 4.01 V | 90 M | 0 |
| 1762148034 | 9 | 22 C | 4.01 V | 100 M | 0 |
| 1762147734 | 9 | 22.2 C | 4.03 V | 100 M | 0 |
| 1762147434 | 9 | 22.7 C | 4.04 V | 90 M | 0 |
| 1762147134 | 8 | 22.8 C | 4.06 V | 110 M | 0 |
| 1762146833 | 6 | 22.7 C | 4.07 V | 80 M | 0 |
| 1762145990 | 9 | 21.7 C | 4.01 V | 90 M | 0 |
| 1762145691 | 9 | 21.8 C | 4.02 V | 100 M | 0 |
| 1762145028 | 8 | 22.3 C | 4.03 V | 80 M | 0 |
| 1762144728 | 8 | 22.6 C | 4.07 V | 80 M | 0 |
| 1762144428 | 8 | 22.6 C | 4.07 V | 90 M | 0 |
| 1762144128 | 9 | 22.6 C | 4.07 V | 90 M | 0 |
| 1762143828 | 8 | 21.7 C | 4.01 V | 90 M | 0 |
| 1762143528 | 8 | 21.8 C | 4.02 V | 100 M | 0 |
| 1762143228 | 8 | 22 C | 4.02 V | 100 M | 0 |
| 1762142928 | 8 | 22.4 C | 4.04 V | 100 M | 0 |
| 1762142628 | 8 | 22.6 C | 4.06 V | 100 M | 0 |
| 1762141423 | 8 | 21.7 C | 4.02 V | 90 M | 0 |
| 1762141122 | 5 | 21.7 C | 4.02 V | 90 M | 0 |
| 1762140823 | 8 | 21.8 C | 4.02 V | 100 M | 0 |
| 1762140522 | 7 | 22.1 C | 4.03 V | 80 M | 0 |
| 1762140221 | 9 | 22.4 C | 4.06 V | 110 M | 0 |
| 1762139921 | 9 | 22.3 C | 4.06 V | 90 M | 0 |
| 1762139079 | 9 | 21.5 C | 4.01 V | 110 M | 0 |
| 1762138778 | 9 | 21.6 C | 4.03 V | 90 M | 0 |
*Used Equation Coefficients:
Sate: 0, 1, 0
Temp: 0, 0.1, -50
Volt: 0, 0.01, 0
Alt: 0, 10, 0
A5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)