This is the latest recevied telemetry packets stored in our database for station/object SP2ROC-13. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | RPM* | VBAT* | TEMP* | TRIP* | Value5* |
|---|---|---|---|---|---|
| 1765982800 | 1201 rpm | 14.95 V | 63 degC | 1.4 km | 0 |
| 1765982740 | 1394 rpm | 14.94 V | 62 degC | 1.3 km | 0 |
| 1765982680 | 1680 rpm | 14.89 V | 61 degC | 1.2 km | 0 |
| 1765982619 | 1680 rpm | 14.89 V | 62 degC | 1.1 km | 0 |
| 1765982559 | 1680 rpm | 14.84 V | 63 degC | 1.1 km | 0 |
| 1765982499 | 945 rpm | 14.8 V | 63 degC | 1 km | 0 |
| 1765982439 | 865 rpm | 14.77 V | 64 degC | 1 km | 0 |
| 1765982319 | 853 rpm | 14.78 V | 64 degC | 1 km | 0 |
| 1765908613 | 0 rpm | 13.26 V | 62 degC | 0 km | 0 |
| 1765908553 | 0 rpm | 13.38 V | 61 degC | 0 km | 0 |
| 1765908493 | 304 rpm | 14.61 V | 60 degC | 0 km | 0 |
| 1765908433 | 850 rpm | 14.7 V | 60 degC | 0 km | 0 |
| 1765908373 | 990 rpm | 13.84 V | 59 degC | 0 km | 0 |
| 1765908313 | 1440 rpm | 13.9 V | 59 degC | 0 km | 0 |
| 1765908033 | 901 rpm | 14.61 V | 55 degC | 0 km | 0 |
| 1765907973 | 1268 rpm | 14.68 V | 54 degC | 0 km | 0 |
*Used Equation Coefficients:
RPM: 0, 1, 0
VBAT: 0, 0.01, 0
TEMP: 0, 1, -100
TRIP: 0, 0.1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)