This is the latest recevied telemetry packets stored in our database for station/object UB0JBX-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | LoadAvg5m* | MemUsed* | Temp* | AudioLvl* | Value5* |
---|---|---|---|---|---|
1746227252 | 1 | 8 % | 49 C | 97 | 0 |
1746226352 | 1 | 8 % | 49 C | 98 | 0 |
1746225451 | 1 | 8 % | 49 C | 97 | 0 |
1746224550 | 1 | 9 % | 49 C | 97 | 0 |
1746223651 | 1 | 9 % | 49 C | 97 | 0 |
1746222751 | 0.9 | 9 % | 49 C | 97 | 0 |
1746221850 | 0.9 | 9 % | 49 C | 97 | 0 |
1746220951 | 1 | 9 % | 51 C | 97 | 0 |
1746220050 | 0.9 | 9 % | 52 C | 97 | 0 |
1746219151 | 0.9 | 9 % | 51 C | 98 | 0 |
1746218250 | 1 | 9 % | 51 C | 98 | 0 |
1746217351 | 1 | 9 % | 52 C | 97 | 0 |
1746216450 | 1.1 | 9 % | 51 C | 96 | 0 |
1746215551 | 1 | 9 % | 51 C | 97 | 0 |
1746214650 | 0.9 | 9 % | 51 C | 97 | 0 |
1746213751 | 0.9 | 9 % | 51 C | 97 | 0 |
1746212851 | 1 | 9 % | 51 C | 95 | 0 |
1746211951 | 0.9 | 9 % | 51 C | 98 | 0 |
1746211051 | 1 | 9 % | 51 C | 97 | 0 |
1746210151 | 1 | 9 % | 51 C | 97 | 0 |
1746209251 | 1 | 9 % | 51 C | 97 | 0 |
1746208351 | 1 | 9 % | 50 C | 97 | 0 |
1746207451 | 1 | 9 % | 50 C | 97 | 0 |
1746206552 | 0.9 | 9 % | 49 C | 97 | 0 |
1746205651 | 0.9 | 9 % | 49 C | 97 | 0 |
*Used Equation Coefficients:
LoadAvg5m: 0, 0.1, 0
MemUsed: 0, 1, 0
Temp: 0, 1, 0
AudioLvl: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)